Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.238
Filtrar
1.
BMC Oral Health ; 24(1): 457, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622649

RESUMO

BACKGROUND: Self-glazed zirconia (SZ) restorations are made by a novel additive three-dimensional gel deposition approach, which are suitable for a straightforward completely digital workflow. SZ has recently been used as minimally invasive veneer, but its clinical outcomes have not been clarified yet. This study aimed to evaluate the preliminary clinical outcomes of SZ veneers compared with the widely used lithium disilicate glass-ceramic veneers made by either pressing (PG) or milling (MG) process. METHODS: Fifty-six patients treated with SZ, PG, and MG veneers by 2 specialists between June 2018 and October 2022 were identified. Patients were recalled for follow-up at least 1 year after restoration. Clinical outcomes were assessed by 2 independent evaluators according to the modified United States Public Health Service (USPHS) criteria. Overall patient satisfaction was assessed using visual analogue scale (VAS), and analyzed by one-way ANOVA. Chi-square test was applied to compare the difference in the success and survival rates among the 3 groups. RESULTS: A total of 51 patients restored with 45 SZ, 40 PG, and 41 MG veneers completed the study, with a patient dropout rate of 8.9%. Mean and standard deviation of follow-up period was 35.0 ± 14.7 months. All restorations performed well at baseline, except for 2 SZ veneers with mismatched color (rated Bravo). During follow-up, marginal discrepancy (rated Bravo) was found in 4 MG veneers and 1 PG veneer, and partially fractured (rated Charlie) was found in another 2 PG veneers. The survival rate of SZ, PG, and MG veneers was 100%, 95%, and 100%, with a success rate of 95.56%, 92.50%, and 90.24%, respectively, none of which were significantly different (p = 0.099 and 0.628, respectively). The mean VAS score of SZ, PG, and MG was 95.00 ± 1.57, 93.93 ± 2.40, and 94.89 ± 2.00 respectively, without significant difference (p > 0.05). CONCLUSION: SZ veneers exhibited comparable preliminary clinical outcomes to PG and MG veneers, which could be considered as a feasible option for minimally invasive restorative treatment.


Assuntos
Falha de Restauração Dentária , Facetas Dentárias , Nitrilas , Zircônio , Humanos , Estudos Retrospectivos , Cerâmica , Teste de Materiais , Desenho Assistido por Computador
2.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622680

RESUMO

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Assuntos
Implantes Dentários , Zircônio , Humanos , Análise de Elementos Finitos , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Estresse Mecânico
3.
J Dent Res ; 103(5): 516-525, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38581213

RESUMO

Titanium (Ti)-based biomaterials lack inherent antimicrobial activities, and the dental plaque formed on the implant surface is one of the main risk factors for implant infections. Construction of an antibacterial surface can effectively prevent implant infections and enhance implant success. Silver nanoparticles (AgNPs) exhibit broad antibacterial activity and a low tendency to induce drug resistance, but AgNPs easily self-aggregate in the aqueous environment, which significantly impairs their antibacterial activity. In this study, UiO-66/AgNP (U/A) nanocomposite was prepared, where zirconium metal-organic frameworks (UiO-66) were employed as the confinement matrix to control the particle size and prevent aggregation of AgNPs. The bactericidal activity of U/A against methicillin-resistant Staphylococcus aureus and Escherichia coli increased nearly 75.51 and 484.50 times compared with individually synthesized Ag. The antibacterial mechanism can be attributed to the enhanced membrane rupture caused by the ultrafine AgNPs on UiO-66, leading to protein leakage and generation of intracellular reactive oxygen species. Then, U/A was loaded onto Ti substrates (Ti-U/A) by using self-assembly deposition methods to construct an antibacterial surface coating. Ti-U/A exhibited excellent antibacterial activities and desired biocompatibility both in vitro and in vivo. The U/A nanocomposite coating technique is thus expected to be used as a promising surface modification strategy for Ti-based dental implants for preventing dental implant infections.


Assuntos
Antibacterianos , Materiais Revestidos Biocompatíveis , Implantes Dentários , Escherichia coli , Nanopartículas Metálicas , Staphylococcus aureus Resistente à Meticilina , Prata , Zircônio , Prata/farmacologia , Implantes Dentários/microbiologia , Antibacterianos/farmacologia , Nanopartículas Metálicas/uso terapêutico , Escherichia coli/efeitos dos fármacos , Zircônio/química , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Estruturas Metalorgânicas/farmacologia , Estruturas Metalorgânicas/química , Animais , Titânio/química , Nanocompostos/química , Propriedades de Superfície , Camundongos , Espécies Reativas de Oxigênio
4.
Shanghai Kou Qiang Yi Xue ; 33(1): 36-39, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583022

RESUMO

PURPOSE: To study the effect of different cleaning methods on the shear bond strength of self-adhesive resin cement to saliva-contaminated high translucency zirconia and surface wettability. METHODS: Eighty zirconia specimens were randomly divided into 5 groups (n=16), i.e., control group(not contaminated), 75% ethanol group,cleaning paste group,airborne-particle abrasion group, and atmospheric pressure cold plasma group. The contact angles was measured, shear bond strength were examined, and fracture types were determined. SPSS 26.0 software package was used for statistical analysis of the data. RESULTS: The atmospheric pressure cold plasma group produced the lowest contact angle(P<0.05). The shear bond strength of the airborne-particle abrasion group, the cleaning paste group and the atmospheric pressure cold plasma group respectively were similar to the control group without significant difference(P>0.05), while those were significantly higher than 75% ethanol group(P<0.05). The mixed fracture mode of the atmospheric pressure cold plasma group evidently increased. CONCLUSIONS: Airborne-particle abrasion, cleaning paste and atmospheric pressure cold plasma overcome the effects of saliva contamination, producing the shear bond strength to zirconia similar to the control group. The atmospheric pressure cold plasma improves hydrophilicity of high translucency zirconia significantly.


Assuntos
Colagem Dentária , Gases em Plasma , Molhabilidade , Propriedades de Superfície , Cimentos de Resina , Zircônio/química , Etanol , Teste de Materiais , Resistência ao Cisalhamento , Análise do Estresse Dentário
5.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(2): 135-141, 2024 Apr 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38597073

RESUMO

Zirconia crown has been widely used in the field of prosthodontics. Traditional zirconia exhibits excellent mechanical properties but lacks translucency. The introduction of transparent zirconia significantly enhances its aesthetic performance. In clinical applications, factors affecting the aesthetic results of full zirconia crown should be comprehensively considered, and the most suitable restoration should be chosen. Additionally, clinicians need to design appropriate tooth preparation dimensions and methods based on an individual patient's actual situation. During the clinical bonding process of zirconia, proper surface treatment of the tooth and restoration is essential. The selection of suitable adhesives is crucial for achieving optimal bonding strength and aesthetics.


Assuntos
Estética Dentária , Dente , Humanos , Coroas , Zircônio
6.
Eur J Med Res ; 29(1): 254, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659074

RESUMO

BACKGROUND: Yttrium-stabilized zirconia (YSZ) and alumina are the most commonly used dental esthetic crown materials. This study aimed to provide detailed information on the comparison between yttrium-stabilized zirconia (YSZ) and alumina, the two materials most often used for esthetic crowns in dentistry. METHODOLOGY: The ground-state energy of the materials was calculated using the Cambridge Serial Total Energy Package (CASTEP) code, which employs a first-principles method based on density functional theory (DFT). The electronic exchange-correlation energy was evaluated using the generalized gradient approximation (GGA) within the Perdew (Burke) Ernzerhof scheme. RESULTS: Optimization of the geometries and investigation of the optical properties, dynamic stability, band structures, refractive indices, and mechanical properties of these materials contribute to a holistic understanding of these materials. Geometric optimization of YSZ provides important insights into its dynamic stability based on observations of its crystal structure and polyhedral geometry, which show stable configurations. Alumina exhibits a distinctive charge, kinetic, and potential (CKP) geometry, which contributes to its interesting structural framework and molecular-level stability. The optical properties of alumina were evaluated using pseudo-atomic computations, demonstrating its responsiveness to external stimuli. The refractive indices, reflectance, and dielectric functions indicate that the transmission of light by alumina depends on numerous factors that are essential for the optical performance of alumina as a material for esthetic crowns. The band structures of both the materials were explored, and the band gap of alumina was determined to be 5.853 eV. In addition, the band structure describes electronic transitions that influence the conductivity and optical properties of a material. The stability of alumina can be deduced from its bandgap, an essential property that determines its use as a dental material. Refractive indices are vital optical properties of esthetic crown materials. Therefore, the ability to understand their refractive-index graphs explains their transparency and color distortion through how the material responds to light..The regulated absorption characteristics exhibited by YSZ render it a highly attractive option for the development of esthetic crowns, as it guarantees minimal color distortion. CONCLUSION: The acceptability of materials for esthetic crowns is strongly determined by mechanical properties such as elastic stiffness constants, Young's modulus, and shear modulus. YSZ is a highly durable material for dental applications, owing to its superior mechanical strength.


Assuntos
Óxido de Alumínio , Coroas , Ítrio , Zircônio , Ítrio/química , Zircônio/química , Óxido de Alumínio/química , Humanos , Teoria Quântica
7.
Biosensors (Basel) ; 14(4)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38667191

RESUMO

Exosomes constitute an emerging biomarker for cancer diagnosis because they carry multiple proteins that reflect the origins of the parent cell. The highly sensitive detection of exosomes is a crucial prerequisite for the diagnosis of cancer. In this study, we report an exosome detection system based on quantum weak value amplification (WVA). The WVA detection system consists of a reflection detection light path and a Zr-ionized biochip. Zr-ionized biochips effectively capture exosomes through the specific interaction between zirconium dioxide and the phosphate groups on the lipid bilayer of exosomes. Aptamer-modified gold nanoparticles (Au NPs) are then used to specifically recognize proteins on exosomes to enhance the detection signal. The sensitivity and resolution of the detection system are 2944.07 nm/RIU and 1.22 × 10-5 RIU, respectively. The concentration of exosomes can be directly quantified by the WVA system, ranging from 105-107 particles/mL with the detection limit of 3 × 104 particles/mL. The use of Au NPs-EpCAM for the specific enhancement of breast cancer MDA-MB-231 exosomes is demonstrated. The results indicate that the WVA detection system can be a promising candidate for the detection of exosomes as tumor markers.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama , Exossomos , Ouro , Nanopartículas Metálicas , Humanos , Neoplasias da Mama/diagnóstico , Feminino , Ouro/química , Nanopartículas Metálicas/química , Biomarcadores Tumorais , Linhagem Celular Tumoral , Limite de Detecção , Zircônio/química
8.
Anal Methods ; 16(15): 2386-2399, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38572640

RESUMO

A novel fluorescence sensor based on a porphyrinic zirconium-based metal-organic framework, L-cysteine-modified PCN-222 (L-Cys/PCN-222), was developed to selectively recognize histidine enantiomers and sensitively detect Hg2+. The dual-functional sensor was successfully prepared via the solvent-assisted ligand incorporation method and characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM), 1H nuclear magnetic resonance (1H NMR) spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, circular dichroism (CD), X-ray photoelectron spectroscopy (XPS), and nitrogen adsorption-desorption analyses. L-Cys/PCN-222 not only showed a higher quenching response for L-histidine than that for D-histidine with a fast fluorescent response rate of <40 s but also exhibited low detection limits for L- and D-histidine (2.48 µmol L-1 and 3.85 µmol L-1, respectively). Moreover, L-Cys/PCN-222 was employed as a fluorescent and visual sensor for the highly sensitive detection of Hg2+ in the linear range of 10-500 µmol L-1, and the detection limit was calculated to be 2.79 µmol L-1 in surface water. The specific and selective recognition of chiral compounds and metal ions by our probe make it suitable for real field applications.


Assuntos
Mercúrio , Estruturas Metalorgânicas , Espectroscopia de Infravermelho com Transformada de Fourier , Histidina , Estruturas Metalorgânicas/química , Zircônio , Cisteína/análise , Cisteína/química , Corantes Fluorescentes/química , Mercúrio/análise
9.
J Mech Behav Biomed Mater ; 154: 106536, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38579394

RESUMO

OBJECTIVE: This study aimed to conduct a comparison of trueness and physical and surface properties among five distinct types of additive manufactured (AM) zirconia crowns and zirconia crowns produced using the subtractive manufacturing (SM). MATERIAL AND METHODS: Zirconia crowns were fabricated using five distinct techniques, each varying in the method of slurry transfer and photocuring source. Each experimental group utilized either one of the four digital light processing (DLP)-based techniques (DLP spreading, DLP spreading gradation, DLP vat and DLP circular spreading) or the stereolithography (SLA)-based technique (SLA spreading). The control (CON) group employed SM. To assess accuracy, trueness was measured between the scan and reference data. To analyze the physical properties, voids were examined using high-energy spiral micro-computed tomography scans, and the crystal structure analysis was performed using X-ray diffraction (XRD). Surface roughness was assessed through laser scanning microscopy. RESULTS: Differences in the trueness of internal surfaces of crowns were found among the groups (P < 0.05). Trueness varied across the measurement surfaces (occlusal, lateral, and marginal) in all the groups except for the DLP spreading gradation group (P < 0.05). Voids were observed in all AM groups. All groups showed similar XRD patterns. All AM groups showed significantly greater surface roughness compared to the CON group (P < 0.001). CONCLUSION: The AM zirconia crowns showed bubbles and a rougher surface compared to the SM crowns. All groups exhibited typical zirconia traits and trueness levels within clinically acceptable limits, suggesting that current zirconia AM techniques could be suitable for dental applications.


Assuntos
Desenho Assistido por Computador , Coroas , Microtomografia por Raio-X , Zircônio , Propriedades de Superfície
10.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598918

RESUMO

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Assuntos
Óxido de Alumínio , Cerâmica , Teste de Materiais , Óxido de Alumínio/química , Cerâmica/química , Propriedades de Superfície , Zircônio/química , Desenho Assistido por Computador , Materiais Dentários
11.
BMC Oral Health ; 24(1): 471, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637799

RESUMO

OBJECT: This study aimed to investigate the changes in the translucency and color of four different multi-layered zirconia materials when the sintering temperature were inaccurate. MATERIALS AND METHODS: Two hundred zirconia samples (11 × 11 × 1.0 mm) of four multi-layered zirconia, Upcera TT-GT (UG), Upcera TT-ML (UM), Cercon xt ML (CX), and Lava Esthetic (LE), were divided into five subgroups according to the sintering temperature: L1 (5% lower temperature), L2 (2.5% lower temperature), R (recommended sintering temperature), H2 (2.5% higher temperature), H1 (5% higher temperature). After sintering, color coordinates were measured. Then the translucency parameter (TP) values, and the color differences (between the inaccurate sintering temperature and the recommended temperature) of each zirconia specimen were calculated. Statistical analysis was performed by using three-way ANOVA tests, the one-way ANOVA, and Tukey's post hoc test. RESULTS: Three-way ANOVA results showed that material type, sintering temperature, specimen section, and their interactions significantly influenced the TP values (except for the interactions of specimen section and sintering temperature) (P < .05). TP values of zirconia specimens were significantly different in the inaccurate sintering temperatures (P < .05), except for the cervical and body sections of UG group (P > .05). Compared with recommended sintering temperature, higher sintering temperature caused higher TP values for CX, but lower for LE. Three-way ANOVA results showed that material type, sintering temperature, and their interactions significantly influenced the ∆E00 values (P < .05). There were no significant differences in ∆E00 values of UM and CX groups at different inaccurate sintering temperatures, and were clinical imperception (except for UM-L1) (∆E00 < 1.25). ∆E00 values of all zirconia specimens showed clinically acceptable (∆E00 < 2.23). CONCLUSION: The deviations in sintering temperature significantly influenced the translucency and color of tested multi-layered zirconia. The trends of translucency in the multi-layered zirconia depended on material type and the color changes of all zirconia materials were clinically acceptable at inaccurate sintering temperatures.


Assuntos
Cerâmica , Zircônio , Humanos , Temperatura , Teste de Materiais , Propriedades de Superfície , Cor
12.
J Adhes Dent ; 26(1): 93-102, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602286

RESUMO

PURPOSE: To investigate the influence of contamination and different cleaning methods on resin bonding to cobalt-chro- mium (CoCr) alloy disks. MATERIALS AND METHODS: A total of 160 CoCr disks were divided into 3 groups. The first group (N = 64) was air abraded with alumina particles and contaminated with a silicone disclosing agent and saliva; the second group (N = 64) was air abraded but not contaminated; the third group (N = 32) was neither air abraded nor contaminated. The first two groups were di- vided into 4 subgroups (N = 16) according to the cleaning method: ultrasonic bath in 99% isopropanol, use of a cleaning suspension of zirconium oxide particles, use of a cleaning suspension based on 10-MDP salt, and treatment with atmo- spheric plasma. The third group was divided into 2 subgroups (N = 16): treatment with atmospheric plasma and no treat- ment. All CoCr specimens were bonded to plexiglas tubes filled with a bonding resin that contained phosphate monomer. Tensile bond strength (TBS) was examined by tensile testing after 3 and 150 days of water storage plus 37,500 thermal cy- cles (N = 8). RESULTS: After contamination, TBS was significantly reduced after 150 days of water storage. Groups without air abrasion showed initially low TBS and debonded spontaneously after 150 days of water storage. CONCLUSION: None of the cleaning methods was able to remove saliva and silicone disclosing agent on CoCr-alloy sur- faces. Surface activation by plasma treatment has no long-term effect on the bond strength.


Assuntos
Resinas Compostas , Colagem Dentária , Cimentos de Resina , Ligas , Abrasão Dental por Ar , Propriedades de Superfície , Água , Resistência à Tração , Silicones , Teste de Materiais , Zircônio , Análise do Estresse Dentário
13.
Biomed Res Int ; 2024: 6670159, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606199

RESUMO

Objective: This research study investigated the effect of new decontamination protocols on the bonding capacity of saliva-contaminated monolithic zirconia (MZ) ceramics cemented with two different monomer-containing self-adhesive resin cements. Materials and Methods: Standardized tooth preparations (4 mm. axial height) were performed for eighty human maxillary premolars under constant water cooling system. Eighty monolithic zirconia crowns (Whitepeaks Supreme Monolith) (n = 8/10 groups) were manufactured by CAD-CAM. Specimens were kept in the artificial saliva at pH = 7.3 for 1 minute at 37°C except control groups. The specimens have not been prealumina blasted and grouped according to cleaning methods and resin cements: control groups (C) (no saliva contamination + GPDM + 4-META (N) (CN) and 10-MDP (M) containing resin cement (CM), alumina blasted (AL) + GPDM + 4-META (ALN) and 10-MDP containing resin cement (ALM), zirconium oxide containing universal cleaning agent (IC) applied + GPDM + 4-META (N) (ICN) and 10-MDP containing resin cement (ICM), pumice (P) applied + GPDM + 4-META (PN) and 10-MDP containing resin cement (PM), and air-water spray (AW) applied + GPDM + 4-META (AWN) and 10-MDP containing resin cement (AWM)). Monobond Plus was applied to all surfaces for 40 seconds before cementation. The thermal cycle was applied at 5,000 cycles after cementation. The crowns were tested in tensile mode at a speed of 1 mm/min. The mode of failure was recorded. SEM examinations were carried out at different magnifications. Data were analyzed using rank-based Kruskal-Wallis and Mann-Whitney tests. Results: No significant differences were found between the surface treatments and between the two types of resin cements. Interaction effects between surface treatments and resin cements were found to be significant by two-way ANOVA analysis. ICM group resulted in significantly better bond strength results compared with CN. ICM was found to result in better bond strength results compared with PM. The combination of universal cleaning agent and 10-MDP containing resin cement had significantly the highest cementation bond strength values. The increasing order of mean tensile bond strength values of decontamination protocols was C < AW < P < AL < IC. The mean tensile bond strength of 10-MDP containing resin cement was slightly higher than GPDM + 4-META containing resin cement. Conclusions: Universal cleaning agents can be preferred as an efficient cleaning method with 10-MDP-containing cement after saliva contamination for better adhesive bond strength of 4 mm crown preparation height of monolithic zirconia ceramics.


Assuntos
Colagem Dentária , Metacrilatos , Cimentos de Resina , Humanos , Cimentos de Resina/química , Saliva , Descontaminação , Teste de Materiais , Zircônio/química , Cerâmica/química , Água/química , Resistência ao Cisalhamento , Propriedades de Superfície , Análise do Estresse Dentário
14.
J Indian Prosthodont Soc ; 24(2): 201-207, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38650346

RESUMO

AIMS: The objectives of the study were to compare the adaptation of presintered zirconia and cobalt- chromium prostheses using microcomputed tomography (µCT), scanning electron microscopy (SEM), and stereomicroscope (SM). MATERIALS AND METHODS: Twenty-four fixed dental prostheses (FDPs) were fabricated on metal abutments, duplicated from maxillary first premolar and first molar prepared on a typodont model. Teeth were reduced to obtain chamfer of 1.2 mm and reduction occlusaly of 2 mm occlusal. Scanning of the abutments was done with random assignment to two groups receiving the FDPs made from soft-milled Co-Cr (n = 12) and zirconia (n = 12). Marginal and internal gaps were assessed using three evaluation techniques (X-ray microcomputer tomography, SEM, and stereomicroscopy). STATISTICAL ANALYSIS USED: Comparison of the results was made using Levene and analysis of variance tests (α =0.05). RESULTS: Irrespective of the material tested, statistical differences were found between the measuring techniques (P = 0.001 overall); the obtained mean gaps were for CT scan (92.60 ± 13.31), for SEM (101.92 ± 23.03), and for SM (113.44 ± 14.68): the multiple comparisons between techniques found a significant difference between CT and SM (P < 0.001), and SEM and SM (P = 0.025). When materials were compared within each measuring technique, Co-Cr showed lower values compared to zirconia in SEM (P < 0.001) and Stereo (P = 0.049); similar results were found in CT. CONCLUSIONS: Results values differed with the chosen measuring technique. Co-Cr prostheses had a better fit than zirconia prostheses in SEM and Stereo. µCT showed comparable results to SEM, smaller than SM results.


Assuntos
Ligas de Cromo , Microscopia Eletrônica de Varredura , Microtomografia por Raio-X , Zircônio , Zircônio/química , Microtomografia por Raio-X/métodos , Ligas de Cromo/química , Humanos , Planejamento de Prótese Dentária/métodos
15.
PeerJ ; 12: e17178, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590702

RESUMO

Gregory's diverticulum, a digestive tract structure unique to a derived group of sand dollars (Echinoidea: Scutelliformes), is filled with sand grains obtained from the substrate the animals inhabit. The simple methods of shining a bright light through a specimen or testing response to a magnet can reveal the presence of a mineral-filled diverticulum. Heavy minerals with a specific gravity of >2.9 g/cm3 are selectively concentrated inside the organ, usually at concentrations one order of magnitude, or more, greater than found in the substrate. Analyses of diverticulum content for thirteen species from nine genera, using optical mineralogy, powder X-ray diffraction, scanning electron microscopy and energy dispersive X-ray spectroscopy, as well as micro-computed tomography shows the preference for selection of five major heavy minerals: magnetite (Fe3O4), hematite (Fe2O3), ilmenite (FeTiO3), rutile (TiO2), and zircon (ZrSiO4). Minor amounts of heavy or marginally heavy amphibole, pyroxene and garnet mineral grains may also be incorporated. In general, the animals exhibit a preference for mineral grains with a specific gravity of >4.0 g/cm3, although the choice is opportunistic and the actual mix of mineral species depends on the mineral composition of the substrate. The animals also select for grain size, with mineral grains generally in the range of 50 to 150 µm, and do not appear to alter this preference during ontogeny. A comparison of analytical methods demonstrates that X-ray attenuation measured using micro-computed tomography is a reliable non-destructive method for heavy mineral quantification when supported by associated analyses of mineral grains extracted destructively from specimens or from substrate collected together with the specimens. Commonalities in the electro-chemical surface properties of the ingested minerals suggest that such characteristics play an important role in the selection process.


Assuntos
Titânio , Zircônio , Animais , Titânio/química , Microtomografia por Raio-X , Minerais/análise , Ferro/química , Ouriços-do-Mar
16.
Georgian Med News ; (347): 151-155, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38609133

RESUMO

One of the significant drawbacks of using zirconium dioxide as a framework for prosthodontic structures is its propensity for breakage. Paradoxically, the higher the optical performance of zirconium dioxide, the more its mechanical durability tends to decrease and vice versa. A detailed analysis of the technological process has uncovered divergent opinions and significant disparities in recommendations concerning the fabrication of zirconium dioxide prosthodontic constructs. There are different recommendations regarding the need for abrasive blasting and regeneration firing. Consequently, conducting an in-depth experimental study on this matter and implementing the resulting findings will significantly contribute to addressing the challenges of prosthodontic rehabilitation for patients utilizing zirconium dioxide.


Assuntos
Prostodontia , Lesões dos Tecidos Moles , Zircônio , Humanos , Temperatura
17.
BMC Oral Health ; 24(1): 472, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641578

RESUMO

PURPOSE: The aim of the current study was to evaluate the effect of simulated gastric acid on the color and translucency of different indirect restorative materials. MATERIALS AND METHODS: A total of 36 disc-shaped samples were cut by using an isomet saw and divided into four equal groups (n = 9) according to the material type: Group Z: translucent zirconia (Ceramill® Zolid ht.+ preshade, Amann Girrbach, Koblach, Austria); Group E: lithium disilicate (IPS e.max CAD, Ivoclar Vivadent AG, Schaan, Liechtenstein); Group C: resin nanoceramic (Cerasmart, GC, Tokyo, Japan); Group P: polyether ether ketone (PEEK) (Bettin Zirconia Dentale Italy) veneered with indirect high impact polymer composite (HIPC) (breCAM HIPC, Bredent GmbH & Co. KG, Germany). The samples were immersed in simulated gastric acid (HCl, pH 1.2) for 96 hours at 37 °C in an incubator. The color change (ΔE00) and translucency (RTP00) were measured every 9.6 hours (one-year clinical simulation) of immersion in simulated gastric acid. RESULTS: For color change (∆E00) and translucency (RTP00) among the tested materials, there was a highly statistically significant difference (P < 0.001) after every year of follow-up. The color change in both Z and G groups was the lowest after 1 year of acid immersion, followed by that in group H, and the highest change in color was recorded in group P. CONCLUSION: High translucent zirconia is recommended in patients who are concerned about esthetic, especially with acidic oral environment.


Assuntos
Cerâmica , Materiais Dentários , Humanos , Teste de Materiais , Zircônio , Propriedades de Superfície , Cor , Desenho Assistido por Computador
18.
Biomed Res Int ; 2024: 7720286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577705

RESUMO

Background: Zirconia, with its excellent mechanical properties, has become a popular choice for esthetic and durable restorations due to the increasing demand of patients. It has overcome most of the limitations of all ceramic restorations. However, bonding to zirconia remains a challenge. Objectives: This study is aimed at assessing the effect of surface treatment with alkaline agents at two different temperatures on microshear bond strength (µSBS) of zirconia to composite resin. Materials and Methods: This in vitro, experimental study was conducted on zirconia blocks measuring 2 × 4 × 8 mm. The blocks were sandblasted with alumina powder and randomly assigned to 5 groups (n = 16 each). The blocks in groups 1 and 2 underwent surface treatment with sodium hydroxide (NaOH) and groups 3 and 4 with zirconium hydroxide (Zr(OH)4) at room temperature and 70°C. Group 5 served as the control group and did not receive any surface treatment. After the application of bonding agent and its light-curing, composite cylinders in plastic tubes were bonded to the surface of each block and cured. After incubation, they underwent µSBS test. Data were analyzed by one-way ANOVA and Tukey's test (alpha = 0.05). Results: The µSBS was significantly higher in all intervention groups than that in the control group (P < 0.05). The µSBS in Zr(OH)4 groups was significantly higher than that in NaOH groups (P < 0.05). The mean µSBS of heated groups was slightly, but not significantly, higher than the corresponding room temperature groups (P > 0.05). Conclusion: Surface treatment of zirconia with NaOH and Zr(OH)4 alkaline agents can increase its µSBS to composite resin; Zr(OH)4 was significantly more effective than NAOH for this purpose, but heating did not have a significant effect on µSBS.


Assuntos
Resinas Compostas , Colagem Dentária , Humanos , Resinas Compostas/química , Propriedades de Superfície , Cimentos de Resina/química , Temperatura , Hidróxido de Sódio , Teste de Materiais , Zircônio/química , Cerâmica/química , Resistência ao Cisalhamento
19.
J Adhes Dent ; 26(1): 79-86, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465402

RESUMO

PURPOSE: This investigation aimed to assess the impact of additive manufacturing-generated surface textures on zirconia bond strength. MATERIALS AND METHODS: Zirconia samples (n = 144) fabricated using digital light-processing (DLP) technology were categorized into 6 groups according to the type of surface conditioning (group NN: no designs, no air abrasion; group NY: no designs, with air abrasion; group GN: groove designs, no air abrasion; group GY: groove designs with air abrasion; group HN: hexagon grid, no air abrasion; group HY: hexagon grid, with air abrasion). Composite resin cylinders were cemented to the treated zirconia surfaces with dual-curing, self-adhesive resin cement (Clearfil SA Luting). The shear bond strength (SBS) was tested after water storage for 3 days or 3 days with an additional 10,000 thermocycles. RESULTS: The zirconia samples fabricated using DLP technology have high accuracy. The SBS of the NY, GY, and HY groups did not significantly differ after 3 days, and neither did the SBS of the NN, GN, and HN groups. The NN, NY, and HY groups exhibited reduced SBS compared to their initial values following artificial aging, while the SBS of the remaining three groups were not diminished. The GY group obtained the highest SBS value after aging. CONCLUSION: Printing grooves with air abrasion can improve the bond strength.


Assuntos
Colagem Dentária , Abrasão Dental por Ar , Propriedades de Superfície , Cimentos de Resina/química , Resinas Compostas , Resistência ao Cisalhamento , Zircônio/química , Teste de Materiais , Análise do Estresse Dentário
20.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38444156

RESUMO

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Assuntos
Cimentos de Ionômeros de Vidro , Boca , Zircônio , Membrana Celular , Coroas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...